2. Using a Lincoln PowerLuber or a manual grease gun, cycle the primary valve (first valve
from the pump element) via the grease fitting. Pump grease for 10 seconds with the
PowerLuber or 10 strokes of a standard grease gun.
3. The last step would be to cycle each secondary valve, again using the PowerLuber or
manual grease gun. You should refer to your owner’s manual to determine the number and
location of the secondary valves. Cycle each valve until fresh grease is seen at a visible
grease point.