Timer Settings and Adjustment
Remove cover to access the timer. The Pause time is set by the blue rotary switch
The pump on-time is set by the red rotary switch
Timer Operation
1. The LED marked “batterylights when power is applied to the PC board.
2. The LED marked “motor” lights when pumping lubricant.
3. Depressing pushbutton for 2 seconds will initiate a manual lube event.
4. Off timer rotary switch, can be adjusted to 15 values, (do not set to “0” )
5. On time rotary switch, can be adjusted to 15 values, (do not use “0” )
IMPORTANT: Do not use the zero position located on the ON or Off timer switch.
Rotary Switch
Values
Switch Position
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Pause Time (Hours)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Switch Position
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
On
-
Time (Minutes)
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
Timer Setting
For the Case Sprayer, set the Pause Time for one hour (switch position1”) and the On-Time for 6
minutes (Switch Position 3)